Daikin Emura is a five-size wall-mounted R32 split family with white, silver and black indoor finishes.

Specifications

SpecificationValue
Typereversible fixed air-to-air heat pump
System arrangementsingle-split pair or compatible multi-split
Indoor-unit typewall-mounted
Product codesFTXJ20/25/35/42/50A2V1B with W, S or B finish suffix; RXJ20/25/35A5V1B and RXJ42/50A2V1B pair outdoor units
Cooling capacity (kW)2.0, 2.5, 3.4, 4.2 and 5.0 nominal
Heating capacity (kW)2.5, 2.8, 4.0, 5.4 and 5.8 nominal
Capacity basisnominal capacities without a stated test point
SEER8.75, 8.74, 8.73, 7.50 and 7.33
SCOP5.15, 5.15, 5.15, 4.60 and 4.60
Cooling energy classA+++ for 20–35; A++ for 42–50
Heating energy classA+++ for 20–35; A++ for 42–50
RefrigerantR32
Indoor sound pressure (dB)cooling silent/high: 19/39, 19/40, 19/41, 21/45 and 24/46
Outdoor sound pressure (dB)heating/cooling: 47/46, 47/46, 49/49, 48/48 and 49/48
Indoor sound power (dB)cooling: 57, 57, 60, 60 and 60
Outdoor sound power (dB)cooling: 60, 60, 61, 63 and 63
Indoor dimensions, width × height × depth (mm)900 × 305 × 212
Outdoor dimensions, width × height × depth (mm)840 × 552 × 350 for 20–35; 954 × 734 × 408 for 42–50
Manufacturer fuse guidance (A)maximum fuse size: 10 for class 20; 13 for classes 25–50
Maximum pipe length (m)20 for classes 20–35; 30 for classes 42–50
Maximum height difference (m)15 for classes 20–35; 20 for classes 42–50
ConnectivityDaikin Onecta app support

Daikin Emura is a wall-mounted R32 family for room heating and cooling. It has five current single-split pairs. The final indoor suffix selects matt white (W), silver (S) or matt black (B) without changing the paired capacity class.

Current single-split pairs

Class Indoor code before finish suffix Outdoor unit Nominal cooling / heating SEER / SCOP Cooling / heating class
20 FTXJ20A2V1B RXJ20A5V1B 2.0 / 2.5 kW 8.75 / 5.15 A+++ / A+++
25 FTXJ25A2V1B RXJ25A5V1B 2.5 / 2.8 kW 8.74 / 5.15 A+++ / A+++
35 FTXJ35A2V1B RXJ35A5V1B 3.4 / 4.0 kW 8.73 / 5.15 A+++ / A+++
42 FTXJ42A2V1B RXJ42A2V1B 4.2 / 5.4 kW 7.50 / 4.60 A++ / A++
50 FTXJ50A2V1B RXJ50A2V1B 5.0 / 5.8 kW 7.33 / 4.60 A++ / A++

For example, the complete white class-25 indoor code is FTXJ25A2V1BW; silver ends S and black ends B. No functional meanings are defined for the A2V1B and A5V1B segments, so each remains intact.

Cabinet, sound and installation differences

Every indoor unit is 900 × 305 × 212 mm. Cooling sound pressure in silent/high modes rises from 19/39 dB(A) on class 20 to 24/46 dB(A) on class 50.

Classes 20, 25 and 35 use an 840 × 552 × 350 mm outdoor cabinet and allow 20 m of pipe with a 15 m level difference. Classes 42 and 50 use a 954 × 734 × 408 mm cabinet and extend those limits to 30 m and 20 m. The manufacturer maximum fuse size is 10 A for class 20 and 13 A for the other four.

Controls and multi-split use

The current family supports Onecta control. Compatible multi-split equipment can connect up to five indoor units, but that is a separate system schedule with its own outdoor code and permitted combinations. The five rows above are single-split pairs.