Specifications
| Specification | Value |
|---|---|
| Type | reversible fixed air-to-air heat pump |
| System arrangement | single-split pair or compatible multi-split |
| Indoor-unit type | wall-mounted |
| Product codes | FTXJ20/25/35/42/50A2V1B with W, S or B finish suffix; RXJ20/25/35A5V1B and RXJ42/50A2V1B pair outdoor units |
| Cooling capacity (kW) | 2.0, 2.5, 3.4, 4.2 and 5.0 nominal |
| Heating capacity (kW) | 2.5, 2.8, 4.0, 5.4 and 5.8 nominal |
| Capacity basis | nominal capacities without a stated test point |
| SEER | 8.75, 8.74, 8.73, 7.50 and 7.33 |
| SCOP | 5.15, 5.15, 5.15, 4.60 and 4.60 |
| Cooling energy class | A+++ for 20–35; A++ for 42–50 |
| Heating energy class | A+++ for 20–35; A++ for 42–50 |
| Refrigerant | R32 |
| Indoor sound pressure (dB) | cooling silent/high: 19/39, 19/40, 19/41, 21/45 and 24/46 |
| Outdoor sound pressure (dB) | heating/cooling: 47/46, 47/46, 49/49, 48/48 and 49/48 |
| Indoor sound power (dB) | cooling: 57, 57, 60, 60 and 60 |
| Outdoor sound power (dB) | cooling: 60, 60, 61, 63 and 63 |
| Indoor dimensions, width × height × depth (mm) | 900 × 305 × 212 |
| Outdoor dimensions, width × height × depth (mm) | 840 × 552 × 350 for 20–35; 954 × 734 × 408 for 42–50 |
| Manufacturer fuse guidance (A) | maximum fuse size: 10 for class 20; 13 for classes 25–50 |
| Maximum pipe length (m) | 20 for classes 20–35; 30 for classes 42–50 |
| Maximum height difference (m) | 15 for classes 20–35; 20 for classes 42–50 |
| Connectivity | Daikin Onecta app support |
Daikin Emura is a wall-mounted R32 family for room heating and cooling. It has five current single-split pairs. The final indoor suffix selects matt white (W), silver (S) or matt black (B) without changing the paired capacity class.
Current single-split pairs
| Class | Indoor code before finish suffix | Outdoor unit | Nominal cooling / heating | SEER / SCOP | Cooling / heating class |
|---|---|---|---|---|---|
| 20 | FTXJ20A2V1B |
RXJ20A5V1B |
2.0 / 2.5 kW | 8.75 / 5.15 | A+++ / A+++ |
| 25 | FTXJ25A2V1B |
RXJ25A5V1B |
2.5 / 2.8 kW | 8.74 / 5.15 | A+++ / A+++ |
| 35 | FTXJ35A2V1B |
RXJ35A5V1B |
3.4 / 4.0 kW | 8.73 / 5.15 | A+++ / A+++ |
| 42 | FTXJ42A2V1B |
RXJ42A2V1B |
4.2 / 5.4 kW | 7.50 / 4.60 | A++ / A++ |
| 50 | FTXJ50A2V1B |
RXJ50A2V1B |
5.0 / 5.8 kW | 7.33 / 4.60 | A++ / A++ |
For example, the complete white class-25 indoor code is FTXJ25A2V1BW; silver ends S and black ends B. No functional meanings are defined for the A2V1B and A5V1B segments, so each remains intact.
Cabinet, sound and installation differences
Every indoor unit is 900 × 305 × 212 mm. Cooling sound pressure in silent/high modes rises from 19/39 dB(A) on class 20 to 24/46 dB(A) on class 50.
Classes 20, 25 and 35 use an 840 × 552 × 350 mm outdoor cabinet and allow 20 m of pipe with a 15 m level difference. Classes 42 and 50 use a 954 × 734 × 408 mm cabinet and extend those limits to 30 m and 20 m. The manufacturer maximum fuse size is 10 A for class 20 and 13 A for the other four.
Controls and multi-split use
The current family supports Onecta control. Compatible multi-split equipment can connect up to five indoor units, but that is a separate system schedule with its own outdoor code and permitted combinations. The five rows above are single-split pairs.
Related entries
Manufacturer and reference sources
Brand
Reference type
Heat-pump or fixed-AC model
Last reviewed
28 Jul 2026
Current status
Current in the manufacturer's UK range.