Knowledge base / Brands / Panasonic / TZ Super-Compact R32

Panasonic · Heat-pump or fixed-AC model

TZ Super-Compact R32

Panasonic TZ Super-Compact R32 is a current wall-mounted reversible AC family with CKE pairs from 2.0 to 7.1 kW.

Specifications

SpecificationValue
Typereversible fixed air-to-air heat pump
System arrangementsingle-split pair
Indoor-unit typewall-mounted
Product codesKIT-TZ20-CKE, KIT-TZ25-CKE, KIT-TZ35-CKE, KIT-TZ42-CKE, KIT-TZ50-CKE, KIT-TZ60-CKE and KIT-TZ71-CKE
Indoor-unit codeCS-TZ20CKEW, CS-TZ25CKEW, CS-TZ35CKEW, CS-TZ42CKEW, CS-TZ50CKEW, CS-TZ60CKEW and CS-TZ71CKEW
Outdoor-unit codeCU-TZ20CKE, CU-TZ25CKE, CU-TZ35CKE, CU-TZ42CKE, CU-TZ50CKE, CU-TZ60CKE and CU-TZ71CKE
Cooling capacity (kW)2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 nominal
Heating capacity (kW)2.70, 3.30, 4.00, 5.00, 5.80, 7.00 and 8.20 nominal
Capacity basisnominal capacities without a stated test point
SEER7.00, 7.30, 7.30, 6.60, 6.90, 6.90 and 6.30
SCOP4.60, 4.60, 4.60, 4.10, 4.50, 4.30 and 4.10
Cooling energy classA++ across the current CKE range
Heating energy classA++ for 20, 25 and 35; A+ for 42, 50, 60 and 71
RefrigerantR32
Indoor sound pressure (dB)cooling quiet/high: 20/37, 20/40, 20/42, 25/44, 33/44, 34/45 and 35/47
Outdoor sound pressure (dB)heating/cooling high: 47/46, 48/47, 50/48, 51/49, 49/48, 51/49 and 54/52
Indoor dimensions, width × height × depth (mm)765 × 290 × 214 for 20–50; 1060 × 295 × 249 for 60–71
Outdoor dimensions, width × height × depth (mm)780 × 542 × 289 for 20–42; 824 × 619 × 299 for 50–60; 875 × 695 × 320 for 71
Connectivitybuilt-in Wi-Fi with Panasonic Comfort Cloud support

TZ Super-Compact is Panasonic’s wall-mounted R32 family for fixed room heating and cooling. The current range has seven complete CKE single-split pairs.

Code map

KIT identifies the complete combination, CS the indoor unit and CU the outdoor unit. The numbers 20, 25, 35, 42, 50, 60 and 71 identify the nominal cooling class. TZ, CKE and the final indoor W remain part of the full product reference.

WKE belongs to an older TZ schedule. Its values must not be combined with the current CKE codes.

Seasonal ratings

SEER, energy class, dimensions and sound differ by size.

Kit Indoor / outdoor pair Nominal cooling / heating SEER / SCOP Cooling / heating class
KIT-TZ20-CKE CS-TZ20CKEW / CU-TZ20CKE 2.0 / 2.70 kW 7.00 / 4.60 A++ / A++
KIT-TZ25-CKE CS-TZ25CKEW / CU-TZ25CKE 2.5 / 3.30 kW 7.30 / 4.60 A++ / A++
KIT-TZ35-CKE CS-TZ35CKEW / CU-TZ35CKE 3.5 / 4.00 kW 7.30 / 4.60 A++ / A++
KIT-TZ42-CKE CS-TZ42CKEW / CU-TZ42CKE 4.2 / 5.00 kW 6.60 / 4.10 A++ / A+
KIT-TZ50-CKE CS-TZ50CKEW / CU-TZ50CKE 5.0 / 5.80 kW 6.90 / 4.50 A++ / A+
KIT-TZ60-CKE CS-TZ60CKEW / CU-TZ60CKE 6.0 / 7.00 kW 6.90 / 4.30 A++ / A+
KIT-TZ71-CKE CS-TZ71CKEW / CU-TZ71CKE 7.1 / 8.20 kW 6.30 / 4.10 A++ / A+

TZ20 to TZ50 share the 765 × 290 × 214 mm indoor cabinet. TZ60 and TZ71 use a wider 1,060 × 295 × 249 mm cabinet. Outdoor dimensions change at TZ50 and again at TZ71.

Every current pair has built-in Wi-Fi with Panasonic Comfort Cloud support.

Reference type

Heat-pump or fixed-AC model

Last reviewed

28 Jul 2026

Current status

Current in the manufacturer's UK range.