Panasonic · Heat-pump or fixed-AC model
TZ Super-Compact R32
Panasonic TZ Super-Compact R32 is a current wall-mounted reversible AC family with CKE pairs from 2.0 to 7.1 kW.
Specifications
| Specification | Value |
|---|---|
| Type | reversible fixed air-to-air heat pump |
| System arrangement | single-split pair |
| Indoor-unit type | wall-mounted |
| Product codes | KIT-TZ20-CKE, KIT-TZ25-CKE, KIT-TZ35-CKE, KIT-TZ42-CKE, KIT-TZ50-CKE, KIT-TZ60-CKE and KIT-TZ71-CKE |
| Indoor-unit code | CS-TZ20CKEW, CS-TZ25CKEW, CS-TZ35CKEW, CS-TZ42CKEW, CS-TZ50CKEW, CS-TZ60CKEW and CS-TZ71CKEW |
| Outdoor-unit code | CU-TZ20CKE, CU-TZ25CKE, CU-TZ35CKE, CU-TZ42CKE, CU-TZ50CKE, CU-TZ60CKE and CU-TZ71CKE |
| Cooling capacity (kW) | 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 nominal |
| Heating capacity (kW) | 2.70, 3.30, 4.00, 5.00, 5.80, 7.00 and 8.20 nominal |
| Capacity basis | nominal capacities without a stated test point |
| SEER | 7.00, 7.30, 7.30, 6.60, 6.90, 6.90 and 6.30 |
| SCOP | 4.60, 4.60, 4.60, 4.10, 4.50, 4.30 and 4.10 |
| Cooling energy class | A++ across the current CKE range |
| Heating energy class | A++ for 20, 25 and 35; A+ for 42, 50, 60 and 71 |
| Refrigerant | R32 |
| Indoor sound pressure (dB) | cooling quiet/high: 20/37, 20/40, 20/42, 25/44, 33/44, 34/45 and 35/47 |
| Outdoor sound pressure (dB) | heating/cooling high: 47/46, 48/47, 50/48, 51/49, 49/48, 51/49 and 54/52 |
| Indoor dimensions, width × height × depth (mm) | 765 × 290 × 214 for 20–50; 1060 × 295 × 249 for 60–71 |
| Outdoor dimensions, width × height × depth (mm) | 780 × 542 × 289 for 20–42; 824 × 619 × 299 for 50–60; 875 × 695 × 320 for 71 |
| Connectivity | built-in Wi-Fi with Panasonic Comfort Cloud support |
TZ Super-Compact is Panasonic’s wall-mounted R32 family for fixed room heating and cooling. The current range has seven complete CKE single-split pairs.
Code map
KIT identifies the complete combination, CS the indoor unit and CU the outdoor unit. The numbers 20, 25, 35, 42, 50, 60 and 71 identify the nominal cooling class. TZ, CKE and the final indoor W remain part of the full product reference.
WKE belongs to an older TZ schedule. Its values must not be combined with the current CKE codes.
Seasonal ratings
SEER, energy class, dimensions and sound differ by size.
| Kit | Indoor / outdoor pair | Nominal cooling / heating | SEER / SCOP | Cooling / heating class |
|---|---|---|---|---|
KIT-TZ20-CKE |
CS-TZ20CKEW / CU-TZ20CKE |
2.0 / 2.70 kW | 7.00 / 4.60 | A++ / A++ |
KIT-TZ25-CKE |
CS-TZ25CKEW / CU-TZ25CKE |
2.5 / 3.30 kW | 7.30 / 4.60 | A++ / A++ |
KIT-TZ35-CKE |
CS-TZ35CKEW / CU-TZ35CKE |
3.5 / 4.00 kW | 7.30 / 4.60 | A++ / A++ |
KIT-TZ42-CKE |
CS-TZ42CKEW / CU-TZ42CKE |
4.2 / 5.00 kW | 6.60 / 4.10 | A++ / A+ |
KIT-TZ50-CKE |
CS-TZ50CKEW / CU-TZ50CKE |
5.0 / 5.80 kW | 6.90 / 4.50 | A++ / A+ |
KIT-TZ60-CKE |
CS-TZ60CKEW / CU-TZ60CKE |
6.0 / 7.00 kW | 6.90 / 4.30 | A++ / A+ |
KIT-TZ71-CKE |
CS-TZ71CKEW / CU-TZ71CKE |
7.1 / 8.20 kW | 6.30 / 4.10 | A++ / A+ |
TZ20 to TZ50 share the 765 × 290 × 214 mm indoor cabinet. TZ60 and TZ71 use a wider 1,060 × 295 × 249 mm cabinet. Outdoor dimensions change at TZ50 and again at TZ71.
Every current pair has built-in Wi-Fi with Panasonic Comfort Cloud support.
Related entries
Manufacturer and reference sources
Brand
Reference type
Heat-pump or fixed-AC model
Last reviewed
28 Jul 2026
Current status
Current in the manufacturer's UK range.