Knowledge base / Brands / Worcester Bosch / CS5800iAW codes

Worcester Bosch · Heat-pump or fixed-AC model

CS5800iAW codes

CS5800iAW is the technical code used for Worcester Bosch Compress 5800i AW outdoor units and their specified indoor arrangements.

Specifications

SpecificationValue
Typetechnical designation within the Compress 5800i AW R290 monobloc family
Rated output (kW)4.31, 6.43 or 7.09 in capacity-code order
Rated-output conditionsA2/W35
SCOP (seasonal coefficient of performance) at 35°C4.53, 4.53 and 4.54 in capacity order in the MCS directory on 23 July 2026
SCOP at 55°C3.03, 3.28 and 3.29 in the same order
Maximum flow temperature (°C)75
RefrigerantR290, GWP 3
Sound power (dB)40 at 4 kW; 42 at 5 and 7 kW
MCS certifiedyes; 11 records under MCS HP0329/05–15, with exact outdoor-only or cylinder-paired model strings
Warranty (years)minimum 2 under current terms; conditional longer routes exist
Supply phasessingle
Capacity codes kW4, 5 or 7
Dimensions, height × width × depth (mm)800 × 1100 × 540 outdoor unit
Weight (kg)143

CS5800iAW is the technical designation for equipment in the Worcester Bosch Compress 5800i AW family. It is not a separate range beside the Compress 5800i.

Reading the code

The outdoor capacities are CS5800iAW 4, 5 and 7. Codes use forms such as ORE-S for an outdoor record and OR-S within a system combination. Indoor equipment then adds its own designation.

The MCS Product Directory reflected that structure on 23 July 2026. Three records covered the 4, 5 and 7 kW outdoor units. Eight further records paired a specific capacity with a named 180, 210 or 250 litre indoor cylinder arrangement. The exact combinations used certificate references MCS HP0329/05 to /15.

Complete certified model string MCS certificate
Bosch CS5800iAW 4 ORE-S MCS HP0329/05
Bosch CS5800iAW 5 ORE-S MCS HP0329/06
Bosch CS5800iAW 7 ORE-S MCS HP0329/07
Bosch CS5800iAW 4 OR180 MCP-S MCS HP0329/08
Bosch CS5800iAW 4 OR210 MCP MCS HP0329/09
Bosch CS5800iAW 5 OR180 MCP-S MCS HP0329/10
Bosch CS5800iAW 5 OR210 MP-S MCS HP0329/11
Bosch CS5800iAW 5 OR250 MP-S MCS HP0329/12
Bosch CS5800iAW 7 OR180 MCP-S MCS HP0329/13
Bosch CS5800iAW 7 OR210 MP-S MCS HP0329/14
Bosch CS5800iAW 7 OR250 MP-S MCS HP0329/15

A design that says only CS5800iAW has therefore not identified the capacity or indoor system. Certification and handover documents need the complete outdoor and indoor codes.

Shared family characteristics

All three outdoor units use R290 in a monobloc refrigerant circuit and a single-phase supply. The 4, 5 and 7 capacity codes provide 4.31, 6.43 and 7.09 kW respectively at A2/W35. MCS seasonal values also differ by capacity. Maximum flow temperature is 75°C. Sound power is 40 dB(A) for the 4 capacity code and 42 dB(A) for the 5 and 7 codes.

The family can use wall-hung, cylinder or hybrid indoor equipment. Sales of the domestic pre-plumbed cylinders named in an August 2025 notice had ceased, while existing warranty support continued. Current indoor-package availability is therefore code-specific.

Current guarantee terms provide a minimum two years and allow longer cover depending on the model and installer accreditation.

Reference type

Heat-pump or fixed-AC model

Last reviewed

31 Jul 2026

Current status

Current in the manufacturer's UK range.