Knowledge base / Brands / Growatt / MIC inverter

Growatt · Solar inverter model

MIC inverter

Growatt MIC is a single-phase grid-tied solar inverter family with X, X2 and X2 Pro variants.

Specifications

SpecificationValue
Typegrid-tied string inverter
Supply phasessingle
Rated AC power (kW)0.75 to 3.3; X2 also has a 0.6 model limited to Germany and the Netherlands
MPPT count1
Maximum input current (A)X: 13; X2: 16; X2 Pro: 18
Maximum efficiency (%)up to 97.6
Euro efficiency (%)X: 96.5 to 97.1; X2: 95.5 to 97.1; X2 Pro: 96.5 to 97.1
Battery compatibleNo
Warranty (years)X: 5 standard, 10 optional; X2: 10; X2 Pro: 8 standard, 10 optional
IP ratingX: IP65; X2 and X2 Pro: IP66
Maximum short-circuit current (A)X: 16; X2 and X2 Pro: 24
Recommended maximum PV power (kW)X: 1.05 to 4.29; X2: 0.9 to 4.95; X2 Pro: 1.5 to 4.95
Operating-temperature range (°C)X: -25 to 60; X2 and X2 Pro: -30 to 60

Growatt MIC is a single-phase string-inverter family for PV. X, X2 and X2 Pro are separate variants with different input-current, enclosure and warranty schedules.

X, X2 and X2 Pro

Suffix Complete power-code schedule
X MIC 750TL-X, 1000TL-X, 1500TL-X, 2000TL-X, 2500TL-X, 3000TL-X, 3300TL-X
X2 MIC 600TL-X2, 750TL-X2, 1000TL-X2, 1500TL-X2, 2000TL-X2, 2500TL-X2, 3000TL-X2, 3300TL-X2
X2 Pro MIC 1000TL-X2 Pro, 1500TL-X2 Pro, 2000TL-X2 Pro, 2500TL-X2 Pro, 3000TL-X2 Pro, 3300TL-X2 Pro

The number is nominal AC watts: MIC 1000TL-X2 Pro, for example, is the 1 kW X2 Pro. The 600 W X2 model is limited to Germany and the Netherlands, so it does not establish general UK availability.

The X2 and X2 Pro variants accept more current per MPPT than X. That distinction can determine whether a higher-current PV module fits the inverter even when its voltage and wattage appear suitable.

Arc-fault protection is optional rather than standard equipment. The full unit code identifies whether that option is fitted.

G98 and G99 evidence by suffix

X and X2 have G98 type-test evidence, while X2 also has G99 evidence. The exact inverter record, all other generation and the aggregate registered capacity determine whether the DNO process is G98 or G99.

MIC has no direct battery connection.

MIC suffix-level UK supply

MIC X, X2 and X2 Pro remained in the worldwide range on 23 July 2026. Current UK supply was unconfirmed for individual suffixes and ratings.

Brand

Growatt

Reference type

Solar inverter model

Last reviewed

31 Jul 2026

Current status

UK new-supply status is unconfirmed.