Knowledge base / Brands / Hitachi Cooling & Heating / Yutaki S

Hitachi Cooling & Heating · Heat-pump or fixed-AC model

Yutaki S

Hitachi Yutaki S is a multi-generation split air-to-water family. Current MCS records give exact SCOP figures for R32 and R410A pairings, including separate S Combi forms.

Specifications

SpecificationValue
Typeair-source, split air-to-water
Supply phasescode-dependent single-phase and three-phase forms
SCOP (seasonal coefficient of performance) at 35°Ccurrent exact MCS records span 3.49 to 4.55, with the value tied to the complete pairing
SCOP at 55°Ccurrent exact MCS records span 2.81 to 4.55, with the value tied to the complete pairing
Maximum flow temperature (°C)60 maximum setting for the documented R32 R1E generation; continuous 60 from about -5 to 25°C outdoors, falling to 45 at -20°C
Heating-water temperature range (°C)maximum setting 60 for the documented R32 R1E generation; the continuous boundary falls to 45 at -20°C outdoor
Domestic-hot-water temperature range (°C)maximum setting 75 for the documented R32 R1E generation; the continuous heat-pump boundary is 55 from -5°C to 35°C, with the upper region requiring backup heat
Minimum operating temperature (°C)-20 for the documented R32 R1E continuous space-heating envelope, with the water-temperature boundary falling at low ambient temperature
RefrigerantR32 or R410A, depending on code generation
MCS certifiedyes; exact Yutaki S and S Combi generation groups were current on 23 July 2026

Yutaki S is a split air-to-water family. Its exact identity combines a RAS outdoor unit with a RWM indoor water module. Yutaki S Combi instead uses a RWD indoor unit with an integrated domestic-hot-water tank.

Current certified generations

The MCS directory held four distinct current groups on 23 July 2026:

Record generation Exact pairing structure Certificate groups and SCOP at 35°C / 55°C
2019 R32 RAS-2WHVRP/RWM-2.0NRE, RAS-2.5WHVRP/RWM-2.5NRE and RAS-3WHVRP/RWM-3.0NRE; S Combi uses matching RWD-NRWE 200S-K or 260S-K units 041-K002-29 to 37; 4.52/3.32, 4.41/3.16 or 4.43/3.12 by size
2021 R32 RAS-2WHVRP1/RWM-2.0R1E, RAS-2.5WHVRP1/RWM-2.5R1E and RAS-3WHVRP1/RWM-3.0R1E; S Combi uses matching RWD-RW1E-220S-K units 041-K002-48 to 50; 4.55/4.55, 4.16/3.16 or 4.12/2.92 by size
2021 R410A RAS-4/5/6WHVNPE single-phase or RAS-4/5/6WHNPE three-phase with matching RWM-N1E or RWD-NW1E-220S-K units; sizes 8 and 10 use three-phase RAS-WHNPE/RWM-N1E pairs 041-K002-51 to 58; 3.49 to 4.19 / 2.81 to 3.25
2025 R32 RAS-4/5/6WHVRP2E single-phase or RAS-4/5/6WHRP2E three-phase with matching RWM-R3E units; S Combi uses matching RWD-RW3E-220S(-K) units 041-K002-73 to 75 a to d; 4.41/3.21, 4.41/3.18 and 4.41/3.18

Heating-only and cooling-kit forms are separate rows in several groups. The certificate suffix identifies that form even where its SCOP values are the same.

Water-temperature boundary

For the documented R32 R1E generation, 60°C is the maximum space-heating setting. The continuous boundary reaches 60°C from about -5°C to 25°C outdoors, then falls to 45°C at -20°C outdoors.

The domestic-hot-water graph has a 75°C maximum setting, but the continuous heat-pump region reaches 55°C from -5°C to 35°C outdoors. The region above it is backup-heater-only operation. Below -5°C, the setpoint must stay inside the continuous boundary if the domestic-hot-water electric heater is disabled. These limits apply to the documented R1E generation only.

Availability

All groups above had current certification records, but that does not confirm current UK supply for every pairing. New-supply availability remained unconfirmed at the review date.

Reference type

Heat-pump or fixed-AC model

Last reviewed

23 Jul 2026

Current status

UK new-supply status is unconfirmed.