SolarEdge S500B is the wider-voltage residential S-series optimiser, with flat- and curved-bracket part-number variants.
Specifications
| Specification | Value |
|---|---|
| Type | residential module-level power optimiser |
| Rated DC power (W) | 500 in the base schedule; 650 for installations after 1 April 2024 |
| Maximum input voltage (V) | 125 |
| MPPT voltage range (V) | 12.5 to 105 |
| Maximum short-circuit current (A) | 15 |
| Maximum efficiency (%) | 99.5 |
| Weighted efficiency (%) | 98.6 |
| Maximum output current (A) | 15 |
| Maximum output voltage (V) | 80 |
| Shutdown output voltage (V) | 1 ± 0.1 per optimiser |
| Bracket variants | flat S500B-1GM4MRM; curved S500B-1GM4MBM |
| Warranty (years) | 25 |
| IP rating | IP68 |
| Operating-temperature range (°C) | -40 to 85, with S500B-specific derating |
SolarEdge S500B is a residential module-level power optimiser for compatible SolarEdge inverters. The B identifies a wider-voltage product rather than a mounting-only variant of S500.
S500B voltage and string counts
S500B accepts a broader module-voltage range and has a different output-voltage ceiling from S500. This changes the permitted optimiser count in parts of SolarEdge’s residential string-design table.
Its input-power row also has the dated installation condition used elsewhere in the current S-series schedule. The higher figure applies after 1 April 2024, while the voltage and current limits remain separate constraints.
Substitution therefore needs the complete optimiser code, PV module electrical data and inverter design table. Matching the nominal wattage in the model name does not establish that S500 and S500B can occupy the same string position.
S500B flat and curved brackets
SolarEdge lists two S500B part numbers with different bracket forms. The bracket suffix identifies the supplied mechanical arrangement; it does not create a different electrical schedule.
Connector type and cable layout also remain part-number details. They come from the exact part number rather than the family page.
S500B shutdown value and UK status
The shutdown value applies when the optimiser is under the disconnected condition in the datasheet.
The current general policy covers eligible power optimisers subject to its terms. S500B remains in the current European residential datasheet, but SolarEdge’s current UK optimiser page lists S550B rather than S500B. Current UK new-supply status is therefore unconfirmed.
Related entries
Manufacturer and reference sources
Brand
Reference type
Solar inverter model
Last reviewed
23 Jul 2026
Current status
UK new-supply status is unconfirmed.