Vitocal 222-G is a compact fixed-output ground source heat pump with an integral 220-litre domestic-hot-water cylinder.

Specifications

SpecificationValue
Typecompact brine-to-water ground source heat pump
Rated output (kW)5.8, 7.5 and 10.4 by exact type
Rated-output conditionsB0/W35
SCOP (seasonal coefficient of performance) at 35°Cup to 5.5, average climate
Maximum flow temperature (°C)65
Sound power (dB)up to 46 at B0/W55
Warranty (years)2 standard; paid extension to 7 subject to terms
TypesBWT 221.B06, BWT 221.B08 and BWT 221.B10
COP B0 W354.6, 4.6 and 4.8
DHW cylinder litres220
Coolingnatural cooling with optional equipment

Vitocal 222-G is an indoor, compact ground source heat pump that combines the heat-pump module and a 220-litre domestic-hot-water cylinder in one casing.

Sizes and ratings

The three types are BWT 221.B06, B08 and B10. Their rated heating outputs at B0/W35 are 5.8, 7.5 and 10.4 kW. The corresponding coefficients of performance are 4.6, 4.6 and 4.8. The family SCOP is up to 5.5 for average-climate, low-temperature operation.

These are source and flow-temperature-specific test results. The ground array, building heat loss, flow temperature and hot-water demand still have to be designed for the installation.

Integrated equipment

The enamelled steel cylinder has a stated capacity of 220 litres. The maximum flow temperature is 65°C.

The published maximum sound power is 46 dB(A) at B0/W55. That is a sound-power rating at a defined operating point, not a room sound-pressure measurement.

Natural cooling is possible with the required accessory and a suitable system.

Status and warranty

Vitocal 222-G remains in Viessmann’s current UK ground source range. Warranty cover is two years as standard with a paid seven-year extension.

Reference type

Heat-pump or fixed-AC model

Last reviewed

31 Jul 2026

Current status

Current in the manufacturer's UK range.