SpecificationValue
Rated power (W)335, 340, 405 or 445 at standard test conditions in the current new-project range
Cell typemonocrystalline silicon; 445AG-M10 uses N-type tunnel oxide passivated contact (TOPCon) cells
Module efficiency (%)20.7 to 23.6, calculated from aperture area
Dimensions (mm)1686 x 1000 x 69 for G1; 1722 x 1134 x 70 for M10 and AG-M10
Power temperature coefficient (%/°C)-0.38 G1, -0.35 M10 or -0.29 AG-M10
Nominal operating cell temperature (°C)44 G1, 45 M10 or 42 AG-M10
Product warranty (years)15
Performance warranty (years)25 for G1/M10; 30 for 445AG-M10
Performance-warranty end value (%)80 at year 25 for G1/M10; 87 at year 30 for 445AG-M10
Bifacialnot claimed; 445AG-M10 has a glass rear cover
Weight (kg)21.7 G1, 25.0 M10 or 28.3 445AG-M10
Characteristic wind resistance (kPa)5.32 G1 or 4.65 M10 and 445AG-M10
Roof pitch (degrees)20 to 60 under standard certificates; separate named-membrane details reach 14 or 15
Roofing-system fire ratingBRoof(t4) external-fire classification in British Board of Agrément certificate 24/7109
MCS certificationMCS British Board of Agrément codes BBA 0032 for modules and BBA 0145 for flashing kits

Clearline Fusion is Viridian Solar’s roof-integrated PV system. The panels and aluminium flashing kits replace the tiles or slates within the array area instead of sitting on rails above the finished roof covering.

Current panel formats

G1 is the narrower format. M10 has a larger footprint, while PV16-445AG-M10 uses the same outside dimensions as M10 but changes its cell technology and rear construction.

The module efficiencies in the datasheets use aperture area. A comparison with a module rated from its full outside area needs the same convention. Temperature behaviour and power-warranty figures also differ by format, so Clearline Fusion is not one interchangeable electrical specification.

The roof-system specification

Portrait and landscape flashing kits are documented for tiled or slated pitched roofs. The standard MCS 012 and British Board of Agrément certificates define the normal pitch range. Viridian’s separate low-pitch technical note gives lower-pitch arrangements with Tyvek Supro or Delta Exxtrem membranes. Those are named construction details rather than a general minimum for every roof.

The British Board of Agrément certificate applies its external-fire classification and wind-resistance values to the panel and flashing-kit system. Roof location, edge zones and the supporting structure still form part of the site design.

The same certificate states that the system has a structural life equivalent to the roof structure under normal service conditions when it is designed, installed and maintained in accordance with the certificate and manufacturer instructions. That is a system assessment, separate from the electrical module warranty.

Warranty and product identity

Current module datasheets use a common product-warranty period but different power-warranty terms for the module formats. The specification table preserves those distinctions.