Ideal Heating · Heat-pump or fixed-AC model
Logic Air 4kW
Ideal Logic Air 4kW, product code AH750664, is the smallest current model in the single-phase R32 monobloc range.
Specifications
| Specification | Value |
|---|---|
| Type | air-source, air-to-water monobloc, inverter-driven |
| Rated output (kW) | 4.0 at 7°C outdoor air with 35°C or 55°C water |
| Rated-output conditions | A7/W35 or A7/W55; output varies across the operating map |
| SCOP (seasonal coefficient of performance) at 35°C | 4.96 in Ideal Rev D; 4.70 in the MCS (Microgeneration Certification Scheme) Product Directory on 23 July 2026 |
| SCOP at 55°C | 3.48 in Ideal Rev D; 3.40 in the MCS Product Directory on 23 July 2026 |
| Maximum flow temperature (°C) | 60 |
| Minimum operating temperature (°C) | -20 |
| Refrigerant | R32, 0.88 kg |
| Sound power (dB) | 52 dB(A), tested to EN 12102-1 |
| MCS certified | yes, MCS reference KIWA 00027/024 HP; current to 25 August 2027 at review date |
| Warranty (years) | up to 7 under current standard homeowner conditions; paid extension available up to 10 |
| Supply phases | single |
| Dimensions, height × width × depth (mm) | 798 × 1095 × 518 in Ideal Rev D |
| Weight (kg) | 86 |
Logic Air 4kW is the smallest current Logic Air model. Its Ideal product code is AH750664 and its MCS certificate reference is KIWA 00027/024 HP.
Output and seasonal figures
Logic Air 4kW produces 4.0 kW at 7°C outdoor air with either 35°C or 55°C water. That point does not describe output across the whole year. Output changes as the outdoor air cools and the required flow temperature rises.
Ideal Rev D gives SCOP (seasonal coefficient of performance) values of 4.96 at 35°C and 3.48 at 55°C. The MCS Product Directory gave 4.70 and 3.40 on 23 July 2026. The datasets conflict, so the figures retain their labels rather than being averaged or substituted for one another.
System and installation context
This is a single-phase R32 monobloc. The 0.88 kg factory refrigerant circuit remains in the outdoor unit. Ideal gives a minimum outdoor operating temperature of -20°C, a maximum flow temperature of 60°C and a minimum hydronic flow of 8.5 litres per minute.
The current Rev D dimensions are 798 mm high, 1,095 mm wide and 518 mm deep. A current serial-specific installation guide instead gives 521 mm depth for the 4 and 5 kW casing, so base, clearance and pipework design follow the document supplied for the exact unit.
Sound power is 52 dB(A). Sound power is a source characteristic, not the sound pressure at a neighbouring window or boundary; distance, reflections, screening and operating condition affect the latter.
Current status and cover
The exact MCS record was current through 25 August 2027 at the review date. Ideal’s current standard homeowner wording offers up to seven years of parts-and-labour cover with registration within 30 days and annual servicing, subject to terms. Its paid extension route lists a ten-year maximum for Logic Air.
Related entries
Manufacturer and reference sources
Brand
Reference type
Heat-pump or fixed-AC model
Last reviewed
31 Jul 2026
Current status
Current in the manufacturer's UK range.