Ideal Logic Air is a current single-phase R32 monobloc air source heat-pump family with 4, 5, 8 and 10 kW capacity names.

Specifications

SpecificationValue
Typeair-source, air-to-water monobloc, inverter-driven
Rated output (kW)4, 5, 8 or 10 capacity names
Rated-output conditionscapacity names, not one test point; exact output varies with outdoor and flow temperature
SCOP (seasonal coefficient of performance) at 35°C4.96, 5.07, 5.16 and 5.19 for 4, 5, 8 and 10 kW respectively
SCOP at 55°C3.48, 3.65, 3.70 and 3.73 in the same capacity order
Maximum flow temperature (°C)60
Minimum operating temperature (°C)-20
RefrigerantR32, 0.88 kg in 4/5 kW and 1.47 kg in 8/10 kW
Sound power (dB)52 for 4/5 kW and 55 for 8/10 kW
MCS certifiedyes; current on 23 July 2026 under KIWA 00027/024 HP, /023 HP, /021 HP and /022 HP
Warranty (years)up to 7 under current standard homeowner conditions; paid extension available up to 10
Supply phasessingle

Logic Air is Ideal Heating’s R32 monobloc air source heat-pump family. The refrigerant circuit stays in the outdoor unit, while water connects it to the heating system and compatible hot-water equipment.

Four current capacities

The range is 4, 5, 8 and 10 kW. Their exact product codes are AH750664, AH750665, AH750666 and AH750667 respectively.

All four Logic Air units use a 230 V single-phase supply. The refrigerant charge is 0.88 kg in the 4 and 5 kW models and 1.47 kg in the 8 and 10 kW models.

Output and water temperature

The capacity name is not a fixed output at every condition. Output changes with outdoor and water temperature. Maximum flow temperature is 60°C and minimum outdoor operating temperature is -20°C.

Minimum water flow is also capacity-dependent: 8.5 litres per minute for the 4 and 5 kW units and 14.5 litres per minute for the 8 and 10 kW units.

Controls, certification and cover

All four exact Logic Air capacities had current MCS Product Directory entries on 23 July 2026 under KIWA 00027/024 HP, /023 HP, /021 HP and /022 HP in capacity order. Standard homeowner cover is up to seven years under the current conditions, subject to terms. A paid extension route has a maximum of ten years.

Reference type

Heat-pump or fixed-AC model

Last reviewed

31 Jul 2026

Current status

Current in the manufacturer's UK range.