Ideal Heating · Heat-pump or fixed-AC model
Logic Air
Ideal Logic Air is a current single-phase R32 monobloc air source heat-pump family with 4, 5, 8 and 10 kW capacity names.
Specifications
| Specification | Value |
|---|---|
| Type | air-source, air-to-water monobloc, inverter-driven |
| Rated output (kW) | 4, 5, 8 or 10 capacity names |
| Rated-output conditions | capacity names, not one test point; exact output varies with outdoor and flow temperature |
| SCOP (seasonal coefficient of performance) at 35°C | 4.96, 5.07, 5.16 and 5.19 for 4, 5, 8 and 10 kW respectively |
| SCOP at 55°C | 3.48, 3.65, 3.70 and 3.73 in the same capacity order |
| Maximum flow temperature (°C) | 60 |
| Minimum operating temperature (°C) | -20 |
| Refrigerant | R32, 0.88 kg in 4/5 kW and 1.47 kg in 8/10 kW |
| Sound power (dB) | 52 for 4/5 kW and 55 for 8/10 kW |
| MCS certified | yes; current on 23 July 2026 under KIWA 00027/024 HP, /023 HP, /021 HP and /022 HP |
| Warranty (years) | up to 7 under current standard homeowner conditions; paid extension available up to 10 |
| Supply phases | single |
Logic Air is Ideal Heating’s R32 monobloc air source heat-pump family. The refrigerant circuit stays in the outdoor unit, while water connects it to the heating system and compatible hot-water equipment.
Four current capacities
The range is 4, 5, 8 and 10 kW. Their exact product codes are AH750664, AH750665, AH750666 and AH750667 respectively.
All four Logic Air units use a 230 V single-phase supply. The refrigerant charge is 0.88 kg in the 4 and 5 kW models and 1.47 kg in the 8 and 10 kW models.
Output and water temperature
The capacity name is not a fixed output at every condition. Output changes with outdoor and water temperature. Maximum flow temperature is 60°C and minimum outdoor operating temperature is -20°C.
Minimum water flow is also capacity-dependent: 8.5 litres per minute for the 4 and 5 kW units and 14.5 litres per minute for the 8 and 10 kW units.
Controls, certification and cover
All four exact Logic Air capacities had current MCS Product Directory entries on 23 July 2026 under KIWA 00027/024 HP, /023 HP, /021 HP and /022 HP in capacity order. Standard homeowner cover is up to seven years under the current conditions, subject to terms. A paid extension route has a maximum of ten years.
Related entries
Manufacturer and reference sources
Brand
Reference type
Heat-pump or fixed-AC model
Last reviewed
31 Jul 2026
Current status
Current in the manufacturer's UK range.