Knowledge base / Brands / Ideal Heating / Logic Air 8kW

Ideal Heating · Heat-pump or fixed-AC model

Logic Air 8kW

Ideal Logic Air 8kW, product code AH750666, is a current single-phase R32 monobloc air source heat pump.

Specifications

SpecificationValue
Typeair-source, air-to-water monobloc, inverter-driven
Supply phasessingle
Rated output (kW)8.0 at 7°C outdoor air with 35°C or 55°C water in Ideal Rev D
Rated-output conditionsthe live HTML table separately shows 8.2 kW; match the exact current document and serial
SCOP (seasonal coefficient of performance) at 35°C5.16 in Ideal Rev D; 5.09 in the MCS (Microgeneration Certification Scheme) Product Directory on 23 July 2026
SCOP at 55°C3.70 in Ideal Rev D; 3.63 in the MCS Product Directory on 23 July 2026
Maximum flow temperature (°C)60
Minimum operating temperature (°C)-20
RefrigerantR32, 1.47 kg
Sound power (dB)55 dB(A), tested to EN 12102-1
MCS certifiedyes, MCS reference KIWA 00027/021 HP; current to 25 August 2027 at review date
Warranty (years)up to 7 under current standard homeowner conditions; optional paid extension page gives a maximum of 10
Dimensions, height × width × depth (mm)1008 × 1095 × 518
Weight (kg)110

Logic Air 8kW is product code AH750666. It is the smaller model in the taller Logic Air casing and remains a 230 V single-phase R32 monobloc.

Output records

Ideal’s March 2026 Rev D sheet gives 8.0 kW at the 7°C outdoor, 35°C water point and at the corresponding 55°C water point. The live HTML product table separately shows 8.2 kW. These values should not be silently merged: the exact current specification and the installation guide for the unit’s serial generation govern the product record and design.

Output also changes away from that test condition. Rev D provides a capacity chart by outdoor and flow temperature, which is the relevant form of data for comparing the unit with a room-by-room heat-loss design.

The current manufacturer seasonal figures are 5.16 at 35°C and 3.70 at 55°C. The MCS record gave 5.09 and 3.63 on 23 July 2026. Each pair remains labelled to its source dataset.

Installation characteristics

The outdoor unit contains 1.47 kg of R32. Its published dimensions are 1,008 mm high, 1,095 mm wide and 518 mm deep, with a weight of 110 kg. Minimum hydronic flow is 14.5 litres per minute.

Ideal gives a -20°C minimum outdoor operating temperature and a 60°C maximum flow temperature. Neither limit says that nominal output is available with both conditions occurring together. The operating map, defrost requirements and available emitter output remain part of the design.

Sound power is 55 dB(A). Location-specific sound pressure depends on operating state, distance and the acoustic setting.

Current record and cover

KIWA 00027/021 HP was current through 25 August 2027 at the review date. Standard homeowner warranty wording is up to seven years with registration within 30 days and annual servicing, subject to terms. Ideal’s optional paid extension gives a maximum of ten years for Logic Air.

Reference type

Heat-pump or fixed-AC model

Last reviewed

23 Jul 2026

Current status

Current in the manufacturer's UK range.