Knowledge base / Brands / Mitsubishi Electric / Ecodan PUZ monobloc

Mitsubishi Electric · Heat-pump or fixed-AC model

Ecodan PUZ monobloc

PUZ is the opening code used by several Mitsubishi Electric Ecodan monobloc outdoor-unit families, so the remaining letters are essential.

Specifications

SpecificationValue
Typeoutdoor-unit code family for monobloc air-to-water heat pumps
RefrigerantR290 or R32, determined by the complete code
MCS certifiedyes; exact PUZ-WZ, PUZ-WM and PUZ-HWM records were present on 23 July 2026
Sub-rangesPUZ-WZ R290; PUZ-WM R32; PUZ-HWM R32 Zubadan
Supply phasesV codes are single phase and Y codes are three phase in current schedules

PUZ is part of the product code on several Mitsubishi Electric Ecodan monobloc outdoor units. It is not a single model and does not establish the refrigerant, capacity or electrical supply without the characters that follow it.

Reading current PUZ families

Current R290 equipment uses PUZ-WZ, with PUZ-WZ50, WZ60, WZ85, WZ100 and WZ120 capacity forms. R32 equipment uses PUZ-WM for the compact and standard families and PUZ-HWM for the 14 kW Zubadan family.

In these schedules, V identifies a single-phase form and Y a three-phase form. The ending can include AA or HA according to family, while -BS identifies coastal protection. These characters should be copied from the rating plate or product record rather than reconstructed from the marketed output.

Sub-range Capacity class Single-phase code Three-phase code
R290 5 kW PUZ-WZ50VAA
R290 6 kW PUZ-WZ60VAA
R290 8.5 kW PUZ-WZ85VAA PUZ-WZ85YAA
R290 10 kW PUZ-WZ100VAA PUZ-WZ100YAA
R290 12 kW PUZ-WZ120VAA PUZ-WZ120YAA
R32 compact 5 kW PUZ-WM50VHA
R32 standard 6 kW PUZ-WM60VAA
R32 standard 8.5 kW PUZ-WM85VAA PUZ-WM85YAA
R32 standard 11.2 kW PUZ-WM112VAA PUZ-WM112YAA
R32 Zubadan 14 kW PUZ-HWM140VHA PUZ-HWM140YHA

Each base code also has an applicable -BS coastal-protection form. The suffix is part of the code and should not be omitted from the equipment record.

Why the complete code matters

The operating envelope changes by sub-range. R290 models operate to -25°C ambient and support water temperatures up to 75°C. The standard R32 range operates to -20°C, while Zubadan uses a -28°C limit. None of those values belongs to PUZ as a whole.

Mitsubishi Electric has also announced the phaseout of its R32 range in favour of R290. This gives the middle letters a lifecycle role as well as a technical one. PUZ-WM and PUZ-WZ identify different appliance families.

Exact PUZ-WZ, PUZ-WM and PUZ-HWM records were current in the MCS (Microgeneration Certification Scheme) Product Directory on 23 July 2026. Certification remains an exact-model check, including the phase and any defined combination.

Reference type

Heat-pump or fixed-AC model

Last reviewed

31 Jul 2026

Current status

Current in the manufacturer's UK range.